The Journal of Dental Panacea

Online ISSN: 2348-8727

CODEN : JDP

The Journal of Dental Panacea (JDP) open access, peer-reviewed quarterly journal, Publish quarterly as Open Access (OA).  Vision of this journal  for better dissemination of knowledge, Journal will be publishing the article ‘Ahead of Print’ immediately on acceptance. In addition, the journal would allow free access (Open Access) to its contents, which is likely to attract more readers and citations to articles published in JDP. Manuscripts must be prepared in accordance with “Uniform requirements” of the The Journal of Dental Panacea as more...

Article type

Original Article


Article page

25-30


Authors Details

Ranjoy Hazra*, Ayush Srivastava, Dinesh Kumar, Amit Khattak, V S Legha, Deepak Kalia, Kamal Verma


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 584

PDF Downloaded: 130


Breaking the code of guided implant surgery with an innovative blend of convenience & precision: A pilot study on accuracy of an ingenious 3d implant surgical guide


Original Article

Author Details : Ranjoy Hazra*, Ayush Srivastava, Dinesh Kumar, Amit Khattak, V S Legha, Deepak Kalia, Kamal Verma

Volume : 4, Issue : 1, Year : 2022

Article Page : 25-30

https://doi.org/10.18231/j.jdp.2022.006



Suggest article by email

Get Permission

Abstract

Statement of Problem: The aim in our pilot research study is to evaluate accuracy of implant placed using guided surgery with an ingeniously developed guide, therefore the deviation between the virtual planning and the postoperative implant position has to be evaluated.
Materials and Methods: 7 patients were randomly selected from the Out Patient Department of our hospital and 10 implants were placed in them with the help of an indigenously developed 3D surgical guide. Pre-operative & Post-operative CBCT was compared in a software for the evaluation of precision. Site specific comparative evaluation was done in 4 parameters i.e., entry deviation, apex deviation, depth deviation in single plane and angulation between long axis of placed and planned implants.
Results: The results were tabulated and standard statistical analyses were done. Mean ± Standard deviation of entry deviation were 0.4 ± 0.29 mm., exit deviation 0.7 ± 0.33 mm., angulation deviation 3 ± 1.7 deg. And depth deviation 0.2 ± 0.13 mm. All the P values were < 0> Conclusion: This evidence backed ingeniously designed implant template reliably guides precise & predictable implant placement in each & every case thus promulgating the best care for all concept further with a vision for the future.


Keywords: Guided Implant surgery, 3D Implant Guide, Ingenious implant guide


How to cite : Hazra R, Srivastava A, Kumar D, Khattak A, Legha V S, Kalia D, Verma K, Breaking the code of guided implant surgery with an innovative blend of convenience & precision: A pilot study on accuracy of an ingenious 3d implant surgical guide. J Dent Panacea 2022;4(1):25-30